• Dse501K Auto Start Stop Genset Controller Diesel Control Power Generator Spare Parts
  • Dse501K Auto Start Stop Genset Controller Diesel Control Power Generator Spare Parts
  • Dse501K Auto Start Stop Genset Controller Diesel Control Power Generator Spare Parts
  • Dse501K Auto Start Stop Genset Controller Diesel Control Power Generator Spare Parts
  • Dse501K Auto Start Stop Genset Controller Diesel Control Power Generator Spare Parts
  • Dse501K Auto Start Stop Genset Controller Diesel Control Power Generator Spare Parts

Dse501K Auto Start Stop Genset Controller Diesel Control Power Generator Spare Parts

Conditions
of Use:
Generator
Usage: Generator
Warranty: 3 Months
Phase: Single Phase/3 Phase
Application: Diesel Generator
Weight: 0.5kg
Customization:
Gold Member Since 2024

Suppliers with verified business licenses

Fujian, China
to see all verified strength labels (11)

Basic Info.

Model NO.
501K
Relative
Deepsea
Voltage
9~36V
Transport Package
Cartons
Specification
0.427kg
Trademark
Shaluo
Origin
China

Product Description

Generator Controller 501K

Generator Controller 501K,The Model

 

501K-1 is a Manual Engine Control Module,Key Start Module: 501K, 701...

Control Modules are provided as follows:
1) Key Start Module: 501K, 701, 702;
2) Auto Start
Module: 5110, 5210;
3) Auto/ AMF Start Module: 5120, 5220, 704                

The Model 501K-1 is a Manual Engine Control Module, which has
been designed to manually control the engine via a key switch on The front
panel. The module is used to start and stop the engine, indicating fault
conditions; automatically shutting down the engine and indicating the engine
failure by LED giving true first up fault annunciation. Operation of

the module is via a three position key switch mounted on the front panel with
STOP(O), RUN(I) and START(II) positions. In the 'O' position the DC supply is
removed from the module and the run relay and alarm output are de-energised. If
the switch is turned to the 'I' position the module is powered up and the run
relay is energised, activating the engine fuel/ignition system and the
protection hold-off timer is initiated. If the switch is moved to the 'II'
position and held against the spring return, a positive supply is applied to the
relevant output terminal and on to the starter motor. Once the engine has
started the switch should be released and allowed to return to the 'I' position.

Operation of any of the following alarms; Low Oil Pressure, High Engine
Temperature, Auxiliary Shutdown, Overspeed (Optional), will cause the run relay
to de-energise.This will remove the fuel/ignition supply from he engine and
bring it to rest. The alarm output will be activated giving a positive DC
output.

Each alarm channel has it's own LED indicator and once
activated no further alarm conditions will be accepted. The alarm output and
relevant LED will remain active until the unit is reset by turning the switch to
the 'O' position.

Overspeed Protection (Optional) is achieved by the
fitment of an additional PCB in the module. This provides integral overspeed
protection derived from either the generator HZ output or the engine magnetic
pick-up (specified on ordering). The overspeed circuit continuously monitors
the engine speed and will shut down the engine immediately if a pre-set speed
level is exceeded. This trip level is adjustable from 90% to 130% of full
rated speed and is suitable of both 50Hz or 60Hz systems.

During engine
cranking and for a short time afterwards the protection hold-off timer is active
and the relevant alarms inputs are inhibited. This enables the engine to start
and achieve normal running conditions. Once the timer has expired the inputs
are enabled providing normal protection from the module.

Charge Failure
warning is also provided by monitoring the WL terminal on the charge alternator.
This operates on a similar principal to the warning lamp fitted in a motor
vehicle, should the output fail the charge fail LED will illuminate. The module
will also provide the alternator excitation current via this connection.

2) SPECIFICATION:

A. DC Supply----9~33V continuous.

B. Alternator Input Range----15~305V AC RMS

C. Alternator Input Frequency---- 50~60Hz at rated engine speed.

D. Magnetic Input Range----0.5V~+/-80V

E. Magnetic Input Frequency----2300Hz~6000Hz

F. Start Relay Output----16 Amp DC at supply voltage

G. Run Relay Output----16 Amp DC at supply voltage

H. Alarm Output----1Amp DC at supply voltage

I. Operating Temperature Range----- -30~70celsius

Dse501K Auto Start Stop Genset Controller Diesel Control Power Generator Spare Parts

Dse501K Auto Start Stop Genset Controller Diesel Control Power Generator Spare PartsDse501K Auto Start Stop Genset Controller Diesel Control Power Generator Spare PartsDse501K Auto Start Stop Genset Controller Diesel Control Power Generator Spare PartsDse501K Auto Start Stop Genset Controller Diesel Control Power Generator Spare Parts
  • Our certificate
Dse501K Auto Start Stop Genset Controller Diesel Control Power Generator Spare Parts

About the company

    Fu'an Shaluo Electronics co.Ltd is a manufacturer of generator accessories, Our company has established a long term and stable business relationship with a number of domestic agents and retailers.

Dse501K Auto Start Stop Genset Controller Diesel Control Power Generator Spare Parts

Factory inspection

The professional person responsible for the quality of supervision and control in the entire process.
 

Element testing

In order to get the superior quality we only use selected good element.
 

Assembles products

Aimed at enabling the production department to manufacture and assemble the product as efficiently as possible.

Dse501K Auto Start Stop Genset Controller Diesel Control Power Generator Spare PartsDse501K Auto Start Stop Genset Controller Diesel Control Power Generator Spare Parts

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now